rdfs:comment"""This connects to the temporal entity which describes when (time interval) the quantity of this data point was, is, or will be in effect. This is the time interval which is covered by the forecast.
This should be equivalent to the time interval covered by the time-series that express the forecast. *A potential application of SHACL?*""";
rdfs:comment"Present Demand Rate that needs to be satisfied by the system";
rdfs:label"Demand Rate";
rdfs:rangexsd:integer;
.
ic-s2:demandrateUpper95PPR
aowl:DatatypeProperty;
rdfs:comment"The upper limit of the range with a 95 % probability that the demand rate is within that range";
...
...
@@ -705,14 +679,16 @@ ic-s2:endOfRange
ic-s2:endTime
aowl:DatatypeProperty;
rdfs:comment"Indicates when the last PPBC.PowerSequence shall be finished at the latest";
rdfs:domain[
aowl:Class;
owl:unionOf(
ic-s2:FillLevelTargetProfile
ic-s2:PowerProfile
ic-s2:PowerForecast
);
];
rdfs:rangexsd:dateTime;
.
ic-s2:explicitControl
aic-s2:ControlScheme;
aowl:NamedIndividual;
rdfs:comment"With implicit control schemes, the CEM receives an incentive signal from a Smart Grid Operator through S1. It is up to the CEM to decide what its response to this signal is. There is no need for the CEM to inform the Smart Grid Operator on what its capabilities are or what actions it is going to take.";
rdfs:label"Explicit Control";
.
ic-s2:fillLevelLabel
aowl:DatatypeProperty;
rdfs:domainic-s2:Storage;
...
...
@@ -734,7 +710,7 @@ ic-s2:fillLevelRange
rdfs:rangexsd:string;
.
ic-s2:fillRate
aowl:DatatypeProperty;
aaowl:ObjectProperty;
rdfs:domain[
aowl:Class;
owl:unionOf(
...
...
@@ -743,7 +719,7 @@ ic-s2:fillRate
);
];
rdfs:label"Fill Rate Level";
rdfs:rangexsd:string;
rdfs:rangeic-s2:NumberRange;
.
ic-s2:finishedAt
aowl:DatatypeProperty;
...
...
@@ -808,12 +784,14 @@ ic-s2:hasCost
aowl:ObjectProperty;
rdfs:comment" Additional costs per second (e.g. wear, services) associated with this operation mode in the currency defined by the ResourceManagerDetails , excluding the commodity cost. The range is expressing uncertainty and is not linked to the operation_mode_factor.";
rdfs:domainic-s2:OperationMode;
rdfs:rangeic-s2:NumberRange;
rdfs:label"hasCost";
.
ic-s2:hasDemandRate
aowl:ObjectProperty;
rdfs:domainic-s2:DemandDrivenProfile;
rdfs:label"has demand rate";
rdfs:rangeic-s2:NumberRange;
.
ic-s2:hasDemandRateForecastValues
aowl:DatatypeProperty;
...
...
@@ -971,12 +949,6 @@ ic-s2:hasOperationModeStatus
rdfs:label"HasOperationModeStatus";
rdfs:rangeic-s2:OperationModeStatus;
.
ic-s2:hasOptimisationScheme
aowl:ObjectProperty;
rdfs:comment"for specifying control type with regards to their optimization scheme implicit, explicit ...";
rdfs:label"Control Scheme";
rdfs:rangeic-s2:ControlScheme;
.
ic-s2:hasPowerConstraints
aowl:ObjectProperty;
rdfs:comment"Identifier of the PEBC.PowerConstraints this PEBC.Instruction was based on.";
...
...
@@ -1146,7 +1118,7 @@ ic-s2:hasUnitOfMeasure
aowl:ObjectProperty;
rdfs:domain[
aowl:Class;
owl:intersectionOf(
owl:unionOf(
saref:Measurement
s4ener:Power
);
...
...
@@ -1167,12 +1139,6 @@ ic-s2:hasValue
rdfs:label"has value";
rdfs:rangexsd:decimal;
.
ic-s2:implicitControl
aic-s2:ControlScheme;
aowl:NamedIndividual;
rdfs:comment"With implicit control schemes, the CEM receives an incentive signal from a Smart Grid Operator through S1. It is up to the CEM to decide what its response to this signal is. There is no need for the CEM to inform the Smart Grid Operator on what its capabilities are or what actions it is going to take.";
rdfs:label"Implicit Control";
.
ic-s2:interruptionEndTime
aowl:DatatypeProperty;
rdfs:domainic-s2:InterruptionInstruction;
...
...
@@ -1191,12 +1157,6 @@ ic-s2:isInterruptible
rdfs:label"is interruptible";
rdfs:rangexsd:boolean;
.
ic-s2:leakBehaviourDetail
aowl:DatatypeProperty;
rdfs:comment"Additional Information about the leakage behaviour of the storage, buffer ...";
rdfs:domainic-s2:Storage;
rdfs:label"Leak Behaviour Detail";
.
ic-s2:leakageRate
aowl:DatatypeProperty;
rdfs:comment"Indicates how fast the momentary fill level will decrease per second due to leakage within the given range of the fill level.";
...
...
@@ -1208,12 +1168,6 @@ ic-s2:limitType
aowl:ObjectProperty;
rdfs:label"Limit Type";
.
ic-s2:localOptimization
aic-s2:ControlScheme;
aowl:NamedIndividual;
rdfs:comment"With local optimization goals, no or only little information from outside the premises is necessary to optimize the energy behaviour.";
rdfs:label"local optimization ";
.
ic-s2:lowerBound
aowl:DatatypeProperty;
rdfs:domains4ener:Power;
...
...
@@ -1441,8 +1395,10 @@ ic-s2:succeeded
rdfs:label"Succeeded";
.
ic-s2:supplyRange
aowl:DatatypeProperty;
aowl:ObjectProperty;
rdfs:comment"The SupplyRate this DDBC.OperationMode can deliver for the CEM to match the DemandRate. The start of the NumberRange is associated with an operation_mode_factor of 0, the end is associated with an operation_mode_factor of 1.";
rdfs:comment"The measurement phase difference is a property that can be measured. It describes the differences between two measurement phases (A, B, C, and Neutral). It's usually measured in voltage.";